Full site calculator

See the numbers for yourself.

Start with the site, not the sector. The same pressure-pipe calculation screens farm groundwater, storm resilience and constrained infrastructure routes.

Water Siphon selected

6.5 m³/minWater Siphon+81 L/s vs natural fall109 L/s · 1.81 m/s · within screening — jump to results
Find the route on a mapOptional — NZ address search and route sketch

Search a New Zealand address, then click along the intended pipe route on the map — intake first, outlet last. Every value the map fills lands in an ordinary editable input.

Click the map to drop route points along the pipe line: intake first (cream marker), outlet last (amber marker). No mouse? Pan and zoom the map, then use “Add point at map centre” — the crosshair marks where it lands.

Drawn route length: 0 m · 0 points

Add at least two route points before checking the profile.

The water-level difference is never taken from the map — ground elevation is not water level. Measure the two water surfaces on site.

Site setup

m
mmThe calculation uses the 277.1 mm internal diameter of catalogue OD315.
mDrives the whole transfer figure. Measure it between the intake and outlet water surfaces, not the ground.
m

Storm event

0 mm to move
ha
mm
mm
Water to move0 mm0 mm connected storm depth

Outlet & baseline

Non-tidal / free outlet
Non-tidal / free outlet
mRaises the intake water level above its normal upstream level for the temporary-stage figure.
mRaises the outlet water level above its normal level for downstream tide, storm surge or receiving drain rise.
mClassifies the gravity outlet only — free outlet, tailwater-controlled or drowned outlet.
h/daySets the daily outlet availability used for drain-time summaries only; it does not change instantaneous pipe capacity.
Advanced Settings

Pipe material

PE SDR17The calculation keeps the entered 277.1 mm internal diameter; nearest catalogue reference OD315 (ID 277.1 mm). PE100 SDR17 / PN10 catalogue OD with supplier mean internal diameter.

Natural fall basis

Sets the partial-pipe basis this figure is computed on; full bore stays reference-only.

Main assumptions

nSets the open-channel roughness the gravity calculation runs at.
mmSets the closed-pipe roughness the Water Siphon and pump-main calculations run at.
KCharges the calculation a minor-loss allowance for entries, outlets, bends, valves, fittings, screens, transitions and manifold effects. Typical installations sit in the 2–4 band.
Estimate ΣK from the routeEstimated ΣK: K = 3.92

Decomposes the minor-loss allowance from the canonical siphon geometry — intake drop, up-line, crest, down-line, exhaust drop — using large-bore flanged loss coefficients.

  • 1 × Submerged intake entranceK 0.50
  • 2 × Intake riser bends (90° long-radius)K 0.56
  • 2 × Up-line grade bends (≤45° sweep)K 0.40
  • 2 × Down-line grade bends (≤45° sweep)K 0.40
  • 2 × Exhaust riser bends (90° long-radius)K 0.56
  • 2 × Gear-driven butterfly isolation valves (open)K 0.50
  • 1 × Submerged outlet exitK 1.00

~16 joints on this route (PE SDR17, 12 m lengths) — joint effects are covered by the clean-pipe roughness basis and are not separately charged.

The Manifold body and its internal non-return valve are not separately modelled in this estimate.

Natural fall1.0%Derived by the calculation from the water-level difference divided by the pipe length; the default 2.0 m difference over 200 m is 1.0%.

Site conditions

°CSets the water viscosity and vapour pressure the calculation uses; the published matrices assume 10 °C.
mSets the atmospheric pressure behind the crest vacuum margin; the published matrices assume sea level.

Pump benchmark

%Sets the efficiency used for the pump-station energy benchmark; it is not a selected pump guarantee.
NZ$/kWhPrices the pump-station operating-cost benchmark only; it does not change hydraulic flow.

Flow window

%Reduces the available flow window for interruptions such as maintenance, tide gates or site operating limits; it affects drain-time summaries only.

Operating comparison

At your current site inputs
Siphon sectionParameter-driven cross-section showing terrain, water levels, pipe route, crest shape and selected drainage method. Site measurements are summarised outside the diagram.

Site screening preview

Site cross-section preview for the selected drainage method.

Outlet may sit below tailwater — submerged discharge is compatible with a primed closed pipe

Steady-state screening estimates for a fully primed closed pipe. The pump row is an energy benchmark, not a pump selection.

The emailed screening report carries the full calculation basis behind its own Water Siphon estimate.

  1. Natural fall25% pipe-flow basis
    1.7m³/min28 L/s · 1.56 m/s
    98× 25,000 L tanks/day
  2. Water SiphonActively primed pressure transfer
    6.5m³/min109 L/s · 1.81 m/s · +81 L/s vs natural fall
    377× 25,000 L tanks/day
  3. Pump stationEnergy benchmark · not a pump selection
    6.11kW147 kWh/day · NZ$44/day · 24 h continuous
    6.5 m³/min109 L/s · 1.81 m/s · matched transfer target

Email me the full screening report

Your estimate is never blurred or held back behind the email. Add your details to receive the complete screening report as a PDF and allow Siphonic Systems to follow up on the site information you submit.

Your details and report are emailed for this enquiry; no visitor account is created. Read the privacy notice.

Read the Engineering ReferenceThe controlled method reference behind this screen: calculation regimes, worked limits and the evidence grade of every field figure.